Project Management

Project Management

Nationwide Installations

Nationwide Installations

Maintenance Contracts

Maintenance Contracts

Next Day Deliveries

Next Day Deliveries

Price Check Guarantee

Price Check Guarantee

Credit Accounts

Credit Accounts

Free Site Survey
Contact Us

Data Centre Power Distribution Units (PDUs)

A range of horizontal and vertical power distribution units (PDUs) including basic, metered, smart and intelligent PDUs is available at Server Room Environments. We supply a wide range of power distribution units, including basic, metered, smart and intelligent PDUs. They are designed for installation in a server rack cabinet and have a range of selections and options. These include outlet socket number and configuration, power metering and environment monitoring, single and three phase supplies. Please let us know if you need assistance organising data centre power distribution management or selecting the right PDU for your server room or data centre project. We provide site surveys and data centre PDU management across the UK and Eire.

Power section(s) Dropdown arrow sprite

FeaturesSubmenu expander (reset)
AccessoriesSubmenu expander (reset)
Inlet TypesSubmenu expander (reset)
Outlet TypesSubmenu expander (reset)
Outlet NumberSubmenu expander (reset)
View All 12
ConnectivitySubmenu expander (reset)
Form FactorsSubmenu expander (reset)
AlertsSubmenu expander (reset)
Price RangeSubmenu expander (reset)
Stock LevelSubmenu expander (reset)
IntegrationsSubmenu expander (reset)
Monitoring SoftwareSubmenu expander (reset)
Branch CircuitsSubmenu expander (reset)
Power SourceSubmenu expander (reset)
BrandsSubmenu expander (reset)
Mains Power SupplySubmenu expander (reset)
Latest ProductsSubmenu expander (reset)

Custom Manufactured PDUs

Most power distribution unit manufacturers offer a wide range of options including colour matched sockets and metal casings. This allows for custom PDUs to be made to order and on relatively short lead times. The majority of PDUs are installed in AC (alternating current) application with some PDUs suitable for (direct current) DC installations.

Power Splitter Boxes

Splitter boxes can be single or three phase (red or blue commando type sockets) and split a source of input power (mains power supply, uninterruptible power supply or generator) into multiple power sources with BS 4343 industrial sockets for load connection.

The input cable is BS 4343 – IEC EN60309-2 and feeds a double-pole MCB protecting each socket. A neon light above each socket indicates power is present. Power splitter boxes can be rack mounted (4U high) or supplied in free-standing steel cases. The MCBs have a screw down cover to prevent accidental operation.

PDU Installation Service

Power distribution units (PDUs) can be installed horizontally or vertically within a server rack, depending on the available space and the number of power outlets required. Horizontal form factor power distribution units are designed for 483Wmm wide cabinets, and vertical form factor PDUs can be of varying lengths defined by the number of power sockets or outlets.

They come with a choice of socket types, including standard IEC connections, and can be supplied with locking power cords for added security.

Most PDUs are connected to an uninterruptible power supply (UPS) to provide backup power during an outage. For installations requiring greater resilience, separate PDUs can be connected to independent power supplies and colour-coded for ease.

Whether you need a basic PDU for straightforward power distribution or an intelligent unit with advanced monitoring and remote management features, our team can help you select and install the right solution for your setup.

Power Management Options

Metered power distribution units (PDUs) allow you to monitor how much electricity your equipment is using. They provide information such as voltage, frequency, power consumption (measured in VA and Watts) and total energy usage (kWh). Depending on the model, you can monitor consumption across the entire PDU or at individual sockets to manage power loads and calculate energy bills for individual tenants.

Intelligent PDUs offer more advanced power management features. They connect to your local network using Simple Network Management Protocol (SNMP), so you can monitor and manage power remotely through the manufacturer’s software or a Data Centre Infrastructure Management (DCIM) system. Depending on the model, you can also remotely switch or reboot connected equipment, either across the entire PDU or through individual outlets.

PDU Projects

Server Room Environments can help in the selection and deployment of power distribution units for your server racks. Please contact us for a project review or to arrange a site survey.

PDU Outlet Sockets and Plugs

The following table shows the main power distribution outlets and plug types available. Please let us know if you need a custom project or cannot find the configuration you need.

Outlet and Plug Types Image Application(s)
IEC320 C13 Female, C14 Male C13 Outlets PCs, small servers and IT peripherals
IEC320 C15 Female, C16 Male C15 Outlets A high temperature version of C13/C14
IEC320 C17 Female, C18 Male C17 Outlets Domestic applications (no earth)
IEC320 C19 Female, C20 Male C19 Outlets Higher power datacentre servers
IEC320 C21 Female, C22 Male C21 Outlets A high temperature version of C19/C20
IEC320 C23 Female, C24 Male C23 Outlets A high temperature version of C23
IEC320 Combi C13, C19 Female, C14 or C20 Male Combi C13-C19 Outlets A C13 and C19 Combination outlet to connect C14 and C20 plugs in the same outlet
IEC320 Combi C13, C15, C19, C21 Female C14, C16, C20, C22 Male Combi Locking C13, C15, C19, C21 Outlets A locking combination outlet
IEC320 BS1363 BS Style UK Socket UK three-square pin plug-in sockets
CEE 7/3 French Schuko type socket French Schuko type E socket
CEE 7/5 German Schuko type socket German Schuko type F socket
NEMA5-20R NEMA Outlet Sockets NEMA sockets
IEC 60309 – IEC 309 IEC60309 Blue Three Phase Outlets Industrial single phase supplies 16A/32A
IEC 60309 – IEC 309 IEC60309 Red Three Phase Outlets Industrial three phase supplies 32A

IEC 60309 is often referred to as an industrial plug and socket and may be used to provide power to higher power PDUs. A typical configuration could use this type of plug and socket arrangement on leads from the output of a UPS maintenance bypass to individual server racks.

As soon as you start to add multiple devices to your server rack, power management can become an issue. The use of Power Distribution Units (PDUs) with some form of metering or intelligent IP connection can help to overcome this and provide a pathway for the future scale-up of your IT deployment.

AC Power Supplies

Most PDUs are powered form a local AC (alternating current) power source via a trailing lead. For a server rack the most common source of AC power is an uninterruptible power supply. The UPS may be a 19inch rackmount type or one installed to power a complete server room or datacentre i.e. a centralised UPS. If a UPS is installed, each PDU outlet is supplying uninterruptible power to the server and IT loads.

Switch Mode Power Supply Ratings and UPS Sizing

When you check a server datasheet, the power supply is often stated at its maximum power rating in Watts. This is the maximum power the switch mode power supply (SMPS) will provide. In practice this figure is not reached for two reasons.

The first is ‘headroom’. The power supply has been chosen as the nearest available or required within the server design specification. Most are sized to allow an 80% headroom. This is sound engineering practice for any electronic or electrical device, including uninterruptible power supplies.

The second is that most power supplies run at half their load in reality. A good rule of thumb therefore is to take the specification rating i.e. 1400W and to divide this by two give and use 50% of the rating for sizing the typical maximum power requirements i.e. 700W. Even then, unless the server is running at full work load it may not be reached.

This rule of thumb applies for most servers, but care should be exercised. If in doubt a check with the server manufacturer’s technical support line or website may provide more information. The Server Room Environments projects team can also provide support, based on installations we have completed and our own knowledge bank.

N+X Power Sources

Some IT servers have redundant power supplies. What this means is that each server has two switch mode power supplies to supply power to internal circuits, microprocessors and fans. The two power supplies typically share the load and if one fails, the other can power the complete load itself.

Where dual power supplies are installed both these can be supplied from two separate power sources. Often these are referred to as ‘A’ and ‘B’ supplies. In the case of PDUs this means using one PDU or set of PDUs on the ‘A’ leg and one on the ‘B’ leg. Each leg may be supplied from different AC power sources i.e. two different UPS to maintain the N+X resilience and the power circuit could also incorporate an automatic or static transfer switch.

Whilst the majority of installed PDUs are for single phase installations, three phase PDUs are also available. Of course, these require a more complex electrical supply in the form of a 3-phase electrical circuit and uninterruptible power supply.
If any loads require a DC source of power, a DC PDU must be installed.

PDU Management and IEC to IEC Power Cords

Even if you only use one power distribution unit it is important to label power cords and to keep a log. The control document identifies the loads connected to the socket outlet(s) and PDU. In complex installations this can make it easier to identify loads for disconnection and which PDU or socket outlet to add new loads to.

Some of the PDU manufacturers our projects team works with provide coloured PDUs. This makes it easier to identify the power legs ‘A’ or ‘B’ used within a server rack. Coloured power cords are also available.

Outlet Monitoring

For complex server room and datacentre installations intelligent PDUs are the preferred option over basic or metered PDUs. Intelligent PDUs have plug-in SNMP cards for network IP management and allow power monitoring at their outlet socket level and at circuit breaker and branch circuit levels. The information gathered can assist with:

  1. Capacity Planning: in terms of having real time and true measurement of the Apparent and Real power used within the server room or datacentre facility
  2. New Device Installation: as soon as a new server, storage or network device is connected its power draw is immediately known
  3. Energy Efficiency: improving server utilisation and removing ‘vampire’ energy usage from the circuits
  4. Security: with access via the front cabinet door controlled over an IP network via the PDU
  5. Prevent Cascade Failures: by setting circuit breaker thresholds, it is possible to mitigate against a single power supply going short-circuit through automatic or manual disconnection
  6. Breaker Failure: breaker monitoring identifies when a specific PDU breaker trips and for it to be reset quickly
  7. Ambient Management: using plug-in temperature probes within the server racks whose analogue data can be read over a network via an intelligent PDU
  8. Branch Circuit Monitoring: for three phase PDUs to ensure branch and phase load balancing
  9. Billing: in colocation datacentres or where there are shared server cabinets
  10. Cabling: with improved labelling and management of power cords

Together these combined factors can help to lower the risk of unplanned for downtime and improve the overall resilience of the IT infrastructure.

Summary

Managing critical power is an important aspect within any server room or datacentre environment. Most organisations will run some form of uninterruptible power and possibly a standby power generator. Within the server rack itself, the benefits of correctly specified and sized power distribution are often overlooked. PDUs are the last segment of any critical power protection plan and when specified and installed correctly, can add to the site’s overall resilience and power management efficiency.

Please contact our Projects Team for more information.

Related FAQs

Earn-sre-points

Earn SRE points on all online purchases with double points on selected products

World Leading Brands
Manufacturer Independent Solutions