08000306838 sales@serverroomenvironments.co.uk

Environment Monitors

Environment monitors provide real time data and information on the environment in which critical systems including IT servers, networking peripherals and Internet of things (IoT) devices are operating. The data can be logged for analysis and instant alarms generated when the recorded measurements rise above pre-set points with alarms issued via email, SMS and phone calls to stored email addresses and phone numbers. Data can also be collected via SNMP over an Ethernet network or pushed to a Cloud-based monitoring portal for access via a suitable HTTP/HTTPS internet browser or mobile phone application. Environment monitors help prevent damage to critical IT operations caused due to sudden temperature and humidity rises, water leaks, smoke and fire and can also help with server capacity planning and energy efficiency.

Monitoring section(s)
Monitor Connectivity (reset)
Monitor Form Factors (reset)
Monitor Alerts (reset)
Brands (reset)
Sensors Per Device (reset)
Digital Inputs / Digital Outputs (reset)

Environment Monitor Comparison Table

Model Available Sensors Built-in Sensors Supplied with these Plug-in Sensors Digital Inputs Digital Outputs Ethernet (RJ45) Protocols Additional Text Alerts
RoomAlert 32E
8 Temperature, Humidity, Power 1xDigital Temperature Sensor, 1xRoom Entry Switch Sensor 16 2 yes SNMP email to SMS portal
RoomAlert 12ER
3 Temperature 1xDigital Temperature Sensor, 1xRoom Entry Switch Sensor 4 1 yes SNMP email to SMS portal
RoomAlert 12E
3 Temperature 1xDigital Temperature Sensor, 1xRoom Entry Switch Sensor 4 1 yes SNMP email to SMS portal
RoomAlert 4ER
2 Temperature 1xDigital Temperature Sensor 1 yes SNMP email to SMS portal
RoomAlert 4E
2 Temperature 1xDigital Temperature Sensor 1 yes SNMP email to SMS portal
RoomAlert 3E 2 Temperature 1 yes SNMP email to SMS portal
RoomAlert 3 WiFi 2 Temperature 1 yes SNMP networked SMS device
Poseidon2 3266
8 Temperature 4 yes SNMP, XML, Modbus/TCP, HWg-Push networked SMS device
Poseidon2 3268
8 Temperature 4 2 yes SNMP, XML, Modbus/TCP, HWg-Push networked SMS device
Poseidon2 3468
8 Temperature 4 2 yes SNMP, XML, Modbus/TCP, HWg-Push networked SMS device
Poseidon2 4002 16 Temperature 12 4 yes SNMP, XML, Modbus/TCP, HWg-Push networked SMS device or GSM modem option
SD-2×1Wire
4 Temperature yes WiFi networked SMS device
STE2
3 Temperature 2 yes SNMP, WiFi networked SMS device
HWg-STE
2 Temperature yes SNMP
HWg-WLD
1 Water yes SNMP networked SMS device
Ares 10 GSM
3 Temperature 12 SIM Card
Ares 12 GSM
14 Temperature 12 SIM Card
Damocles2 MINI
4 2 yes SNMP, XML, Modbus/TCP, HWg-Push networked SMS device
Damocles2 1208
12 8 yes SNMP, XML (HTTPs), Modbus/TCP, MQTT, HWg-Push networked SMS device