Climate change is driving up ambient temperatures and causing extreme weather patterns. For server room and datacentre operators, these environmental issues are placing a greater strain on their critical infrastructure systems. Server room air conditioning systems are placed under greater load during heatwave conditions and UPS systems must use their battery power more often to cover small power outages and complete mains power failures.
Hot and Cold Aisle Monitoring
Using AKCP Cabinet Thermal Maps and Differential Air Pressure Sensors we can model what is happening witin your server racks and containment aisles. The Thermal Map sensors include 6 sensors for temperature and humidity and the Cabinet Analysis sensor monitors differential air pressure. The combination allows data to be gathered to calculate Delta-T between the inlet and outlet air temperatures, monitor humidity and changes in air pressure.
-
Solutions (39)
- Temperature & Humidity (31)
- Water Leakage Detection (28)
- Server Rack Monitoring (29)
- BESS Systems (6)
- Generators (4)
- Remote Outdoor Cabinets (10)
- UPS and Rectifier Batteries (7)
- UPS / CSS / CPSS Systems (6)
- Branch Power Circuits (10)
- Door Access/Security (27)
- Energy Monitoring (3)
- Power Supplies (AC/DC) (32)
- Data Centres (8)
- Industrial Sites (26)
- Laboratories (21)
- Pharmaceutical (21)
- Solar PV Farms (6)
- Warehouses (20)
- Base Units (39)
- Sensors (149)
- Accessories (173)
- Services
Protecting Hot and Cold Aisles
The AKCP environmental monitoring solution for data centre containment aisles is a sensorProbe+ SPX8. To this we can connect AKCP cabinet thermal map sensors. These consist of a pair of 6 temperature & humidity sensors to monitor the front and back of a cabinet, at the top, middle and bottom. The two sensor strings connect to an ACKP splitter unit which then connects to the sensorProbe+ base in unit.
For a complete environmental view of what is happening within the cabinet and aisles, a cabinet analysis sensor is added to monitor for differential air pressure changes. The combined sensors provide a complete view of the data centre white space allowing you to monitor environmental performance in line with ASHRAE recommendations.
Installation
The temperature & humidity sensors are installed within the cabinets. Additional temperature or humidity sensor can be installed within the hot and/or cold aisles suspended from the containment ceiling or cable trays.
The SPX8 has 8 ports which can be increased to 16 ports using additional built-in sensor port modules (factory option) or the addition of a base expansion unit (BEB). The total number of cabinet thermal maps that can be connected to a single sensorProbe+ is 16 giving 144 sensors. Sensors are NIST certified.
Please contact our Projects team for more information on cabinet thermal maps and air pressure monitoring for hot and cold aisle containment systems.