Price Check Guarantee

Price Check Guarantee

Nationwide Installations

Nationwide Installations

Next Day Deliveries

Next Day Deliveries

Free Expert Advice

Free Expert Advice

Free Site Survey

Netio PowerDIN ZP3 3-Phase Remote Power Switching DIN Rail Mount PDU with Energy Metering

SKU: POWERDIN-ZP3
Prices from £190.00 including VAT or £228.00 ex. VAT
Prices from £228.00 inc. VAT
Prices from £190.00 ex. VAT
Total price delivered from £196.95 ex. VAT or £236.34 inc. VAT
Total price delivered from £236.34 inc. VAT
Total price delivered from £196.95 ex. VAT

More than 1 unit wanted? Contact us for a discount code.
Reseller pricing available on this model.

In stock deliveryIn stock, despatch within 5 working days
Lead times delivery guide

Lead Times & Delivery Guide – contact us for a specific day/time

Price check guarantee

Our Price Check Guarantee ensures value for money when buying this product

Reward points
Earn 95 SRE Reward Points when you buy this product
£

Pay using our secure payment gateway with a debit/credit card, your Amazon, Google or PayPal account, make a BACS payment, open a credit account or request a leasing quotation.

6
6 year warranty when purchasing this product
Payment Methods – All major cards accepted
Payment footer
Description
Specification

PowerDIN ZP3 is a 3-phase 40Vac 3×16A DIN Rail mount power switching device. The device can also act as a switching device in a single-phase system with three independent channels (3x 230V/16A).

The PowerDIN ZP3 can be remotely controlled and monitored via a web interface and the NETIO Cloud or an Open API. Each of the 3 outputs can be switched ON/OFF independently. The DIN rail mount device has two dry contact digital inputs (DI – including S0 pulse counts) that can be read remotely. Integration with third-party systems can be achieved via standard protocols including JSON, Modbus/TCP, SNMP, MQTT-flex, and Telnet. A NETIO Cloud ‘welcome credit’ is provided free of charge for each connected device, calculated to cover about 3 years of operation.

PowerDIN ZP3 is also equipped with two Digital Inputs (DI), those can be used for direct connection to a NETIO sensors, NETIO nBus (device daisy-chaining feature), or an S0 counter

PowerDIN ZP3 Features

  • Three 240Vac outputs that can be switched OFF via a built-in relay for remote reboots
  • Two digital inputs (DI) to connect push-buttons or SO meters
  • LAN or WiFi connection with NFC configuration
  • Built-in web interface
  • Open API: MQTT-flex, Modbus/TCP, Telnet, JSON, XML, SNMP
  • Energy metering tracks the energy flow in both directions separately (with two separate kWh counters); an additional, user-resettable counter is also provided
  • PowerUp State: defined output states after power-up and remembers the last state
  • PowerUp Delay: with outputs switched ON after a delay) to allow a switched sequence after a power outage
  • Firmware can be upgraded over the Web, configuration can be imported and exported
  • Independent Output Control (IOC)
  • Zero Voltage Switching Outputs (ZVS)
  • Mobile app: NETIO Mobile2 for Android and iOS
  • Internet Service: NETIO Cloud

Typical Applications

  • LED Wall installations remote reboot (Power OFF, ON, RESTART)
  • LED Wall energy consumption metering
  • Industrial equipment electrical consumption monitoring
  • Electric car slow charging control
  • Electricity switching 3-phase system in electrical cabinets and LV switchgear
  • Metering and switching three phase outputs
  • Output control using Open API (JSON, Modbus/TCP, SNMP, MQTT-flex, Telnet, etc)
  • Integration with various third-party programs and applications.
  • Remote Energy Consumption Monitoring: in one or two circuit branches
  • Measuring Electricity Consumption above 16A: by connecting the pulse output of a 3-phase electricity meter to In1 or In2
  • Output Control: each output can be switched ON/OFF or power-cycled (e.g. to restart all appliances connected to the same circuit branch) from the web interface or the NETIO Cloud service

Digital Inputs

  • DI (Digital Inputs) In1 and In2 : can be used to connect any dry contact – SI input states are shown in the Open API and each input includes an S0 pulse counter for monitoring a water or electricity meter

Zero Voltage Switching (ZVS)

PowerDIN ZP3 uses ZVS to control the exact time the mechanical relay contacts close or open an ensures that this is at the zero crossing on the AC sinewave. ZVS reduces wear and tear on the relays and reduces the negative effects of inrush current i.e. circuit breaker nuisance tripping.

LAN/WiFi Connection

PowerDIN ZP3 can be connected to a local network for monitoring and control. If a live IP/Ethernet (RJ45) connection is detected, the DIN rail mount device uses the LAN. If the RJ45 is disconnected PowerDIN ZP3 switches to the WiFi connection. For WiFi, PowerDIN ZP3 has an internal antenna; limited range if installed within a metal cabinet. The WiFi connection can be configured to use AP mode, or with the NFC interface and the NETIO Mobile2 app.

  • For WiFi setup without NFC, PowerDIN ZP3 has a built-in WiFi AP as well as a wizard guide WiFi network selection and connection configuration
  • With the NETIO Mobile2 app and an NFC-capable phone, PowerDIN ZP3 can be connected to a WiFi network in 60 seconds

Event Scheduler Function

The Scheduler Function allows the powering ON or OFF of each output to programmed into a weekly day schedule at specific times. This can be a useful features to save energy and periodically reboot connected devices.

  • Each output connection has its own schedule
  • The scheduler works without an internet connection; a time source (NTP server) is needed such as a local ADSL broadband or WiFi router
  • Netio Cloud can also be use to control the outputs when the scheduler is active

Integrations and Drivers

Netio have a number of integrations and drivers for third-party products, services and cloud applications:

  • Smart home automation
  • Intelligent buildings
  • Audio visual AV systems
  • Server rooms and data centres
  • Retail kiosks, signage and lighting

Typical Applications

  • LED Wall installations remote reboot (Power OFF, ON, RESTART)
  • LED Wall energy consumption metering
  • Industrial equipment electrical consumption monitoring
  • Electric car slow charging control
  • Electricity Metering and switching 1-phase system in electrical cabinets and LV switchgear
  • Metering and switching single phase outputs
  • Output control using Open API (JSON, Modbus/TCP, SNMP, MQTT-flex, Telnet, etc)
  • Integration with various third-party programs and applications.
  • Remote Energy Consumption Monitoring: in one or two circuit branches
  • Measuring Electricity Consumption above 16A: by connecting the pulse output of a 3-phase electricity meter to In1 or In2
  • Output Control: each output can be switched ON/OFF or power-cycled (e.g. to restart all appliances connected to the same circuit branch) from the web interface or the NETIO Cloud service
  • Battery Charger Control: for example for e-bikes, caravans, boats and other devices with energy storage up to 3.6kW (230Vac/16A)

PowerDIN Models

SKU Phases Switched Power Outputs Metered Channels DO Relay
Outputs
DI Inputs LAN WiFi Web NETIO Cloud WatchDog Scheduler Mobile App Open API
PowerDIN 4PZ 1 2 2 2 2 1 Yes Yes Yes Ping / Power Yes iOS / Android 10 Protocols
PowerDIN ZP3 3 3 2 1 Yes Yes Yes Ping / Power Yes iOS / Android 10 Protocols
PowerDIN ZK3 3 3 3 2 1 Yes Yes Yes Ping / Power Yes iOS / Android 10 Protocols