AKCP Cabinet Analysis Sensors for Differential Air Pressure, Temperature and Humidity




Lead Times & Delivery Guide – contact us for a specific day/time

Our Price Check Guarantee ensures value for money when buying this product

Pay using our secure payment gateway with a debit/credit card, your Amazon, Google or PayPal account, make a BACS payment, open a credit account or request a leasing quotation.

The Cabinet Analysis Sensor combines differential air pressure and cabinet thermal maps into one smart sensor. The CAS sensor pack includes a string of 6x Temp sensors and 2x Humidity for cabinet front and rear data collection and 2x differential pressure sensors to monitor changes in air pressure between the front and rear of a server rack. The solution is ideal for cold and hot aisle containment monitoring to monitor temperature, humidity and that the airlfow is as desinged, from the front inlet to the rear of the rack.
The data collected can be viewed as a server rack map within the AKCP Quicklime software. This providesa visual representation of your cabinets and cold and hot aisle containment with airflow, temperature and humidity differentials.
Differential Temperature (Delta T)
The server cabinet thermal map provides temperature values at the front and rear, top, middle and bottom of a server cabinet. The Delta T value for the front-to-rear temperature differential is automatically calculated and can be displayed with animated arrows on the rack cabinet map screen.
Differential Pressure (Delta D)
Air naturally flows from areas of high to low pressure. In a server cabinet environment, it is imperative for efficient cooling to check that there is higher pressure at the front of the cabinet and lower pressure at the rear to ensure that air from the hot and cold aisles is not mixing.
Rack Maps and Containment Views
Using AKCP Quicklime or a compatible Data Centre Infrastructure Management (DCIM) platform, dedicated rack maps displaying Cabinet Analysis Sensor data can be configured to provide a visual data representation for each server rack and cabinet in a data centre. For data centres using hot and cold aisle containment, containment views can be configured to provide a sectional view of the server racks and containment aisles.








































